    Details

    The PKG100-CO2 Carbon Dioxide transmitter is a perfect device for air quality control and CO2 accumulation prevention in the environment.
    Areas of application:
    • Public buildings, theaters, cinemas, concert halls
    • HVAC in office buildings, hotels
    • Factories, refrigeration facilities
    • Greenhouses and mushroom plants
    Functions and features:
    • Designed for refrigeration and safety applications
    • Duct mount robust enclosure
    • Dual wavelength high range NDIR sensor
    • Excellent long-term stability, long calibration interval
    • Two analog outputs configurable as 4-20 mA or 0-10 V
    • 1 x RS485 Interface (Modbus RTU)

     

    Ordering information

    PKG100-CO2 - X . X
    Mounting type
    duct-mount DM
    wall-mount WM
    remote probe* RP
    Calibration type
    calibration type A
    (should be calibrated once in 5 years)
    A
    calibration type B**
    (should be calibrated once a year)
    B
    * Default cable length is 3 m. (custom cable length on request)
    ** this type of sensor can only be used if the CO2 level decreases to fresh air level at least once a week

    Variants

    PKG100-CO2-DM.A duct-mount, calibration type A
    PKG100-CO2-DM.B duct-mount, calibration type B
    PKG100-CO2-WM.A wall-mount, calibration type A
    PKG100-CO2-WM.B wall-mount, calibration type B
    Detected gas Carbon dioxide CO2
    Calibration Carbon dioxide CO2
    Sensor type long-life nondispersive infrared (NDIR) sensor
    Sampling method diffusion
    Detection ranges standard 400…5000 ppm
    on request 400…10000 ppm
    Accuracy, max. 400…5000 ppm ± (50ppm +3% of measuring value)
    400…10000 ppm ± (100ppm +5% of measuring value)
    Power supply 12 / 24 (11...30) V DC
    Power consumption, max. 2 W
    Resolution 1 ppm
    Response time approx. 60 seconds
    Warm-up time, max. 1 minute
    Signal update every 15 s
    Self-diagnostics full functionality check at start-up
    Analog outputs Number 2
    Output signal 4-20 mA / 0-10 V
    (user settable, freely configurable scales)
    Permissible load 4-20 mA RL < (U - 2 V) / 22 mA
    0-10 V RL > 250 kohm
    Fieldbus Interface RS485
    Protocol Modbus RTU
    Galvanic isolation none
    Remote probe Cable length* 3 m
    Dimensions Ø28 x L80 mm
    IP code IP20
    Cable connections screwless spring loaded terminals
    Enclosure Material grey ABS
    Mounting type wall-mount / duct-mount
    Schutzart IP65
    CE marking according to 2014/30/EU and EN61326-1 requirements
    Operating environment industrial indoor and outdoor locations
    Lifetime, min. 15 years
    Dimensions 82 x 80 x 55 mm
    * custom cable length on request