Industrial Remote I/O Modules

Mx210 Series with Ethernet

mx210_101_402

Modbus TCP, MQTT, IIoT...

Has the time come?

Industrial Ethernet has kept surpassing traditional fieldbus architectures year on year since 20181, and thus, becomes the leading connection methodology in plants around the world. Since the Industrial Ethernet is now an up-and-coming star on the industrial automation stage, we introduce remote Ethernet I/O Modules based on Modbus TCP.
It’s time to stop lagging behind and become a part of the trend, together with akYtec and Mx210 Series I/O Modules.

1 according to HMS Networks, an international company in the field of industrial communications

Why Modbus TCP?

Modbus TCP is an open, globally accepted, simple, vendor-neutral communication protocol. Being on the top 4 of industrial ethernet protocols, Modbus TCP is a ‘de-facto’ automation standard. If your system is not deterministic and doesn’t require high-level real-time performance, it’s not reasonable to employ high-end ethernet protocols, such as EtherCat, Profinet, Ethernet/IP. Why would you pay more if Modbus TCP is enough for your task?

Remote I/O modules Mx210 come in useful if you need:

Flexibly extend existing I/Os
of a PLC-based system

mx210
The Ethernet I/O-Modules of the MX210 series are available in different variants depending on the combination of the number, type, and properties of their inputs and outputs.
The analog inputs and outputs of the respective device variant are individually configurable to several signal types, which adds to the flexibility of your system even more. You can create your own I/O-type combinations within a single device to match the requirements of the task.

Migrate from Fieldbus to Industrial Ethernet
or create a PLC-based system on Industrial Ethernet

As compared to fieldbus-based networks, industrial Ethernet communications are much faster, have greater bandwidth, easier upward integration, unlimited node counts, and more topology options. Also, Ethernet networks are far easier to deploy and use than fieldbus technologies.

Smoothly integrate
into IIoT infrastructure

Thanks to the MQTT communication protocol, an Mx210 module can connect to any MQTT brokers providing integration between factory installations and IT-systems / IIoT applications, and thus a range of possibilities, such as remote monitoring and control via any browser-enabled devices, PCs, smartphones, tablets, etc.
The MQTT technology is easy-to-learn and very smooth at its use:

Connect field I/Os without PLC

Any Mx210 remote I/O module can operate as a standalone device on a factory floor or in a process plant without any need of a PLC, connecting field I/Os directly to a SCADA system, cloud infrastructure, or an MQTT broker.

What modules we offer:

  • Analog input modules
    (MV210-101)

    8 individually configurable analog inputs to connect a wide range of sensors, such as RTDs (Pt100/1000, Ni100/1000), TCs, and signals 0-1 V, 0(4)-20 mA.
    mx210
  • Digital input modules
    (MV210-202/204/212/214)

    Up to 32 inputs to connect switch contacts as well as NPN or PNP transistors. High-speed counting with 100-KHz inputs to connect encoders or pulse counters.
    mx210
  • Digital input module
    (MV210-221)

    • - 6 input to connect switch contacts as well as NPN transistors (support for 400-Hz-counting)
    • - 9 digital inputs for connecting 230 V AC signals for:
      • determination of the presence or absence of voltage in the network
      • phase break diagnostics in a three-phase network
      • phase rotation control
      • voltage switching counter
      • other needs
    mx210

Digital input/output modules
(MK210-311/312)

Convenient combination of inputs and outputs:
  • - 6 or 12 digital inputs implemented to be connected to switch contacts or NPN/PNP sensors. No power required to supply the inputs
  • - 8 or 4 digital outputs (relay)
mx210

Digital output modules
(MU210-401/402/410)

8 or 16 digital outputs (relay or transistor outputs). The maximum current load is 5 A at 250 V AC or 3A at 24 V DC. Support for pulse-width modulation (PWM) for PID control, etc.
mx210

Analog output module
(MU210-501)

8 analog individually configurable outputs: 0(4)-20 mA, 0-1(10)V. Support for pulse-width modulation (PWM) for PID control, etc. Configurable output signal update rate.
mx210

Technical data

INPUT MODULES
MV210- 101 202 204 212 214 221
Number of inputs 8 20 20 32 32 15
Input signal RTD, TC,
4-20mA, etc
Switch contact, NPN/PNP Switch contact, NPN Switch contact, NPN/PNP Switch contact, NPN 230 VAC signals,
dry contact,
NPN
Pulse frequency, max. - 100 kHz 400 Hz 100 kHz 400 Hz 400 Hz
Pulse length, min. - 5 µs (1-8 DI),
1 ms (9-20 DI)
1 ms 5 µs (1-8 DI),
1 ms (9-32 DI)
1 ms 1 ms
Integrated voltage source - 24±3 VDC 24±3 VDC only for NPN inputs 24±3 VDC 24±3 VDC only for NPN inputs
PDF Manual Manual Manual Manual Manual Manual
Select your device
DIGITAL INPUT & OUTPUT MODULES
MK210- 311 312
Digital inputs 6 12
Input signal Switch contact,
NPN
Switch contact,
NPN/PNP
Pulse frequency, max. - 100 kHz
Pulse length, min. 1 ms 5 µs (1-8 DI),
1 ms (9-12 DI)
Integrated voltage source 24±3 VDC only for NPN inputs 24±3 VDC
Digital outputs 8 4
Type Relay (NO) Relay (NO)
Permissible load 5 A, 250 VAC cosϕ > 0.4,
3 A, 30 VDC
5 A, 250 VAC cosϕ > 0.4,
3 A, 30 VDC
PDF Manual Manual
Select your device
OUTPUT MODULES
MU210- 401 402 410 501
Number of outputs 8 16 16 8
Output signal Relay (NO) Relay (NO) Transistor 0(4)-20 mA, 0-1(10)V
Permissible load 5 A, 250 VAC cosϕ > 0.4,
3 A, 30 VDC
5 A, 250 VAC cosϕ > 0.4,
3 A, 30 VDC
100 mA, 10...36 VDC 800 mA 10...36 VDC -
Pulse frequency, max. 1 Hz 1 Hz 60 000 Hz 10 000 Hz -
Pulse length, min. 50 ms 50 ms 10 µs 1 µs -
PDF Manual Manual Manual Manual