If you're in the market for input/output modules for your distributed automation systems, akYtec's MX110 series offers a reliable and cost-effective solution. These modules are suitable for decentralized data acquisition and process control, providing a practical supplement to existing systems or the foundation for new setups.

Here's how to pick the right one.

How to pick the right input/output module How to pick the right input/output module

Analyze System Needs:

Evaluate the number and type of input and output points your system requires. MX110 modules come in digital and analog variants to accommodate various signal types.

 

Digital vs. Analog:

Choose digital modules for simple on/off signals and analog modules for variable signal sensors. Fast analog inputs are available for applications needing rapid processing.

 

System Compatibility:

Ensure that the MX110 modules are compatible with your existing SCADA system, HMI, or PLC, specifically supporting the RS485 interface and Modbus RTU/ASCII communication protocols.

 

Advanced Features:

For more than basic data acquisition, opt for modules with pulse counters, sensor state diagnosis, PWM on digital outputs, additional logic functions, transmission protocol auto-detection, and fail-safe features to enhance system resilience.

 

By following these guidelines, you can ensure you select the MX110 module that best fits your automation requirements, delivering reliability and flexibility to your system.

fish industry

For example, if you are in the fish industry, working at a fish processing factory, you probably have a large fridge hall where you need to control several parameters in a decentralized system:

  • The condition of the tile freezers (freezing, defrosting, or stopping);
  • The condition of the refrigerant circulation pumps (operation, accident, or shutdown);
  • The current level value in the circulation receiver;
  • The upper emergency level in the circulation receiver;
  • Status of the refrigerant level sensor in the circulation receiver;
  • The current value of the suction and discharge pressure of the units;
  • Compressor status (operation, compressor blocking stopped);
  • Compressor performance (50, 75, 100%);
  • The status of the condenser fan groups (operation or shutdown).

In general, you’ll have around 45-48 digital signals you need to acquire and send to your PLC. To cover this case, you’ll need to organize 3 control cabinets: the first one will manage the control of the freezers' solenoids, the second will be responsible for condensate management, and the third will control the circulation receiver. To manage it, you can just place our digital input module MV110-24.16DN in every control cabinet, ensuring all signals are acquired and successfully transferred to the PLC.

 

For any of your applications, you can select modules according to these tables:

 

MV110 DIGITAL INPUT MODULES (DI, MODBUS RTU/ASCII, RS485)

Feature

MV110-24.16D

MV110-24.16DN

Power Supply

24 (18 ... 30) V

24 (20...28) V DC

Power Consumption, Max

6 W

6 W

Inputs

Digital: 16

Digital: 16

Interface

RS485

RS485

Connection

D+, D-

D+, D-

Protocols

Modbus RTU / ASCII

Modbus RTU / ASCII

Baud Rate

115.2 kBd

2.4...115.2 kbit/s

Dimensions

63 x 110 x 75 mm

63 x 110 x 75 mm

Weight

Approx. 0.5 kg

Approx. 240 g

Material

Plastic

Plastic

Input Signal

Switch contact, NPN

Switch contact (NPN/PNP)

Galvanic Isolation

2300 V

1500 V, in groups of 4

Pulse Frequency, Max

1 kHz

1 kHz

Pulse Length, Min

0.5 ms

0.5 ms

Current, Max

7 mA

8.5 mA (with 27 V)

 

MV110 ANALOG INPUT MODULES (AI, MODBUS RTU/ASCII, RS485)

Feature

MV110-24.8A

MV110-24.8AS

Power Supply

24 (20...28) V DC

24 (20...28) V DC

Power Consumption, Max.

6 W

6 W

Analog Inputs

8

8

Input Signals

RTD, TC, Position encoders, Standard signals

Standard signal 0-10 V, 0-5 mA, 0(4)-20 mA

Measurement Error, Max.

RTD: ±0.25%, TC: ±0.5%, Encoders: ±0.25%, Signals: ±0.25%

± 0.25%

Sampling Time per Input, Max.

RTD: 0.9 s, TC/Encoders/Signals: 0.6 s

5±2 ms

Galvanic Isolation

1500 V

Between groups: 750 V, From power supply: 3000 V

Resolution

16 bit

10 bit

Interface

RS485

RS485

Protocol

Modbus RTU / ASCII

Modbus RTU / ASCII

Baud Rate

2.4...115.2 kBit/s

2.4...115.2 kBit/s

Ambient Temperature

-20...+55 °C

-20...+55 °C

Storage Temperature

-25...+55 °C

-25...+55 °C

Humidity

Up to 80%, non-condensing

Up to 80%, non-condensing

IP Code

IP20

IP20

Dimensions

63 x 110 x 75 mm

63 x 110 x 75 mm

Weight

Approx. 240 g

Approx. 240 g

Material

Plastic

Plastic

 

MU110 DIGITAL OUTPUT MODULES (DO, MODBUS RTU/ASCII, RS485)

Feature

MU110-24.8R

MU110-24.8K

MU110-24.16R

MU110-24.16K

Power Supply

24 (20...28) V DC

24 (20...28) V DC

24 (20...28) V DC

24 (20...28) V DC

Power Consumption, Max.

6 W

6 W

12 W

12 W

Digital Outputs

8

8

16

16

Output Type

Relay (NO)

NPN Transistor

Relay (NO)

NPN Transistor

Permissible Load

4 A at 250 V AC or 24 V DC

400 mA, 60 V DC

3 A at 250 V AC or 30 V DC

400 mA, 60 V DC

Galvanic Isolation

In groups of 4

In groups of 4

In groups of 4

In groups of 4

Interface

RS485

RS485

RS485

RS485

Protocol

Modbus RTU / ASCII

Modbus RTU / ASCII

Modbus RTU / ASCII

Modbus RTU / ASCII

Baud Rate

2.4...115.2 kBit/s

2.4...115.2 kBit/s

2.4...115.2 kBit/s

2.4...115.2 kBit/s

Ambient Temperature

-20...+55 °C

-20...+55 °C

-20...+55 °C

-20...+55 °C

Storage Temperature

-25...+55 °C

-25...+55 °C

-25...+55 °C

-25...+55 °C

Humidity

Up to 80%, non-condensing

Up to 80%, non-condensing

Up to 80%, non-condensing

Up to 80%, non-condensing

IP Code

IP20

IP20

IP20

IP20

Dimensions

63 x 110 x 75 mm

63 x 110 x 75 mm

63 x 110 x 75 mm

63 x 110 x 75 mm

Weight

Approx. 300 g

Approx. 300 g

Approx. 300 g

Approx. 300 g

Material

Plastic

Plastic

Plastic

Plastic

 

MU110 ANALOG OUTPUT MODULES (AO, MODBUS RTU/ASCII, RS485)

Feature

MU110-24.6U

MU110-24.8I

Power Supply

24 (18...29) V DC

24 (18...29) V DC

Power Consumption, Max.

6 W

6 W

Analog Outputs

6

8

Output Signal

0-10 V

4-20 mA

Permissible Load

12...36 V DC, min. 2000 ohm

10...36 V DC, 0...1300 ohm

Accuracy

±0.5%

±0.5%

Resolution

10 bit

10 bit

Interface

RS485

RS485

Protocol

Modbus RTU / ASCII

Modbus RTU / ASCII

Baud Rate

2.4...115.2 kBit/s

2.4...115.2 kBit/s

Ambient Temperature

-20...+55 °C

-20...+55 °C

Storage Temperature

-25...+55 °C

-25...+55 °C

Humidity

Up to 80%, non-condensing

Up to 80%, non-condensing

IP Code

IP20

IP20

Dimensions

63 x 110 x 75 mm

63 x 110 x 75 mm

Weight

Approx. 240 g

Approx. 240 g

Material

Plastic

Plastic

 

MK110 INPUT AND OUTPUT MODULES (DI/O, MODBUS RTU/ASCII, RS485)

Feature

MK110-24.8D.4R

General

Power Supply

24 (20...28) V DC

Power Consumption, Max.

6 W

Digital Inputs

8

Type

Switch contact, NPN

Galvanic Isolation

None

Insulation Strength

1500 V

Pulse Frequency, Max.

1 kHz

Pulse Width, Min.

0.5 ms

Current, Max.

7 mA

Lead Resistance, Max.

100 ohm

Digital Outputs

4

Type

Relay

Permissible Load

4 A, 250 V AC cosϕ > 0.4 or 24 V DC

Communication

Interface

RS485

Protocol

Modbus RTU / ASCII

Baud Rate

2.4...115.2 kBit/s

Environment

Ambient Temperature

-20...+55 °C

Storage Temperature

-25...+55 °C

Humidity

Up to 80%, non-condensing

IP Code

IP20

Enclosure

Dimensions

63 x 110 x 75 mm

Weight

Approx. 260 g

Material

Plastic