Due to the programmable relay PR114 users can cost-effectively implement from simple to complex control tasks in various application areas. Universal input and outputs as well as the universal power supply make the PR114 particularly flexible. Free akYtec ALP software is used for programming.
-
-
-
The SMI2 is a universal display unit for monitoring industrial processes. It has an RS485 interface and the measured values can be displayed up to four digits. The SMI2 has a compact, standardised design and fits into a standard 22.5 mm borehole for signal lamps. This provides quick and easy installation and many displays can be accommodated in a control cabinet door or on a panel.Learn More
-
The ITP11-W is a universally-applicable display unit for monitoring of industrial processes. Scaling and square root functions are available. The ITP11-W is designed to be connected to sensors or transmitters with a 4-20 mA output.Learn More
-
The digital input module MV210 has 20 or 32 digital inputs able to connect switch contacts as well as NPN or PNP transistors. To communicate the input data to a controller, an Ethernet port and Modbus TCP are at your disposal. The module requires 24V DC input power and can operate in the temperature range between -40 and +55 °C.Learn More
-
The analog input module MV110-24.8A has 8 analog inputs which can be connected to various types of RTDs, thermocouples, position encoders, and standard signals. The more detailed list of possible connection types can be found in the technical data. In addition, the inputs can be used as digital inputs. The available voltage value at the outputs is 10...36 V DC. The module requires 24 V DC power supply and supports Modbus RTU/ASCII communication via a serial RS485 interface. The enclosure provides IP20 rating and can be operated in the temperature range between -20 and +55 °C.Learn More
-
The BPS210-60.S is a two phase power supply unit with an integrated output-relay fit for the demanding solutions. It offers maximum functionality for applications in complex systems and machines. The power supply steps down the voltage from 230V AC to 24V DC. Output voltage can be adjusted with a trimmer (+-8%). Thanks to the extremely space-saving narrow design, they are particularly suitable for industrial applications in switch boxes or in small control cabinets. To increase the output power, several power supply units of the same type can be connected in parallel. Warning! Improper use can lead to hazards such as short circuit, fire, electric shock, etc.Learn More
-
The analog input module MV210-101 has 8 analog inputs which can be connected to various types of RTDs, thermocouples, position encoders, and standard signals. To communicate the input data to a controller, an Ethernet port and Modbus TCP are at your disposal. The module requires 24V DC input power and can operate in the temperature range between -40 and +55 °C.Learn More
-
The digital I/O-Module MK210 has 6 or 12 digital inputs which are implemented as switch contacts and NPN. In addition, there are also 8 or 4 digital outputs (relay) available. To communicate the input data to a controller, an Ethernet port and Modbus TCP are at your disposal. The module requires 24V DC input power and can operate in the temperature range between -40 and +55 °C.Learn More
-
The analog output module MU110-501 has 8 analog outputs (0(4)-20 mA, 0-1(10)V). To communicate the input data to a controller, an Ethernet port and Modbus TCP are at your disposal. The module requires 24V DC input power and can operate in the temperature range between -40 and +55 °C.Learn More
-
The digital output module MU210 has 8 or 16 digital outputs (relay or transistor outputs). The max. current load is 5 A at 250 V AC or 3A at 24 V DC. To communicate the input data to a controller, an Ethernet port and Modbus TCP are at your disposal. The module requires 24V DC input power and can operate in the temperature range between -40 and +55 °C.Learn More
-
The analog input module MV110-24.8AS has 8 analog inputs (0-10 V, 0-5 mA, 0(4)-20 mA). The module requires 24 V DC power supply and supports Modbus RTU/ASCII communication via a serial RS485 interface. The enclosure provides IP20 rating and can be operated in the temperature range between -20 and +55 °C.Learn More
-
The digital input module MV110-24.16DN has 16 digital inputs able to connect switch contacts as well as NPN or PNP transistors. All the inputs are galvanically isolated in groups of 4. To communicate the input data to a controller, a serial RS485 port and Modbus RTU/ACSII are at your disposal. The module requires 24V DC input power and can operate in the temperature range between -20 and +55 °C.Learn More
-
The digital output module MU110-24.8R has 8 digital outputs (relay). The max. current load is 4 A at 250 V AC or 24 V DC. The outputs are galvanically isolated in groups of 4. The module requires 24 V DC power supply and supports Modbus RTU/ASCII communication via a serial RS485 interface. The enclosure provides IP20 rating and can be operated in the temperature range between -20 and +55 °C.Learn More