Welcome to akYtec!
 
Call us now: +49 (0) 511 / 16 59 672-0

All Products

Items 16 to 30 of 44 total

Page:
  1. 1
  2. 2
  3. 3
  • PVT10 Humidity and Temperature Transmitter
    Humidity and Temperature Transmitter
    16DO16DOEtherCATrelayEtherCAT16DOrelayrelay16DOrelayrelayrelayrelayrelayrelayrelay
    Learn More

  • SMI2 RS-485 Display
    The SMI2 is a universal display unit for monitoring industrial processes. It has an RS485 interface and the measured values can be displayed up to four digits. The SMI2 has a compact, standardised design and fits into a standard 22.5 mm borehole for signal lamps. This provides quick and easy installation and many displays can be accommodated in a control cabinet door or on a panel.
    LED colorModbus protocolRS485 interfacethe process display can be used as a Modbus Master or Slavepower supply 24 V DCeasy mounting in a Ø22.5 mm holequick mountingcompact designthe process display can be installed into a push-button boxIP65 rated enclosureCharacter height 14 mmAmbient temperature
    Learn More

  • ITP11-W Process indicator 4-20 mA (loop-powered)
    The ITP11-W is a universally-applicable display unit for monitoring of industrial processes. Scaling and square root functions are available. The ITP11-W is designed to be connected to sensors or transmitters with a 4-20 mA output.
    LED color4-20 mA inputDIN rail mountingTube mountingWall mountingaccuracy 0.2%IP65 rated enclosureCharacter height 14 mmAmbient temperature
    Learn More

  • MU210 Digital Output Module
    The digital output module MU210 has 8 or 16 digital outputs (relay or transistor outputs). The max. current load is 5 A at 250 V AC or 3A at 24 V DC. To communicate the input data to a controller, an Ethernet port and Modbus TCP are at your disposal. The module requires 24V DC input power and can operate in the temperature range between -40 and +55 °C.
    8 or 16 digital outputsRelay or transistor outputsEthernet interfacebypassModbus TCPUSB interfacebuilt-in real-time clockLoggingsoftware at no chargeAmbient temperatureDIN rail mountingWall mounting
    Learn More

  • MV210 Digital Input Module
    The digital input module MV210 has 20 or 32 digital inputs able to connect switch contacts as well as NPN or PNP transistors. To communicate the input data to a controller, an Ethernet port and Modbus TCP are at your disposal. The module requires 24V DC input power and can operate in the temperature range between -40 and +55 °C.
    20 or 32 digital inputsNPN input typePNP input typeEthernet interfacebypassModbus TCPUSB interfacebuilt-in real-time clockLoggingsoftware at no chargeAmbient temperatureDIN rail mountingWall mounting
    Learn More

  • MV110-24.8A Analog input module
    The analog input module MV110-24.8A has 8 analog inputs which can be connected to various types of RTDs, thermocouples, position encoders, and standard signals. The more detailed list of possible connection types can be found in the technical data. In addition, the inputs can be used as digital inputs. The available voltage value at the outputs is 10...36 V DC. The module requires 24 V DC power supply and supports Modbus RTU/ASCII communication via a serial RS485 interface. The enclosure provides IP20 rating and can be operated in the temperature range between -20 and +55 °C.
    8 analog inputshandrelayRS485 interfaceModbus RTU/ASCIIAmbient temperatureDIN rail mountingWall mounting
    Learn More

  • MV210-101 Analog Input Module
    The analog input module MV210-101 has 8 analog inputs which can be connected to various types of RTDs, thermocouples, position encoders, and standard signals. To communicate the input data to a controller, an Ethernet port and Modbus TCP are at your disposal. The module requires 24V DC input power and can operate in the temperature range between -40 and +55 °C.
    8 analog inputshandUniversal inputsEthernet interfacebypassModbus TCPUSB interfacebuilt-in real-time clockLoggingsoftware at no chargeAmbient temperatureDIN rail mountingWall mounting
    Learn More

  • MK210 Digital I/O-Module
    The digital I/O-Module MK210 has 6 or 12 digital inputs which are implemented as switch contacts and NPN. In addition, there are also 8 or 4 digital outputs (relay) available. To communicate the input data to a controller, an Ethernet port and Modbus TCP are at your disposal. The module requires 24V DC input power and can operate in the temperature range between -40 and +55 °C.
    6 digital inputsNPN input typePNP input type (for MK210-312)8 digital outputsRelay outputEthernet interfacebypassModbus TCPUSB interfacebuilt-in real-time clockLoggingsoftware at no chargeAmbient temperatureDIN rail mountingWall mounting
    Learn More

  • MV110-24.8AS analog input module
    The analog input module MV110-24.8AS has 8 analog inputs (0-10 V, 0-5 mA, 0(4)-20 mA). The module requires 24 V DC power supply and supports Modbus RTU/ASCII communication via a serial RS485 interface. The enclosure provides IP20 rating and can be operated in the temperature range between -20 and +55 °C.
    8 analog inputs4-20 mA input signal0-10 V input signalRS485 interfaceModbus RTU/ASCIIHigh sampling rateAmbient temperatureDIN rail mountingWall mounting
    Learn More

  • MV110-24.16DN Digital Input Module
    The digital input module MV110-24.16DN has 16 digital inputs able to connect switch contacts as well as NPN or PNP transistors. All the inputs are galvanically isolated in groups of 4. To communicate the input data to a controller, a serial RS485 port and Modbus RTU/ACSII are at your disposal. The module requires 24V DC input power and can operate in the temperature range between -20 and +55 °C.
    16 digital inputsNPN input typePNP input typeRS485 interfaceModbus RTU/ASCIIAmbient temperatureDIN rail mountingWall mounting
    Learn More

  • MU110-24.8R Digital  output module
    The digital output module MU110-24.8R has 8 digital outputs (relay). The max. current load is 4 A at 250 V AC or 24 V DC. The outputs are galvanically isolated in groups of 4. The module requires 24 V DC power supply and supports Modbus RTU/ASCII communication via a serial RS485 interface. The enclosure provides IP20 rating and can be operated in the temperature range between -20 and +55 °C.
    8 digital outputsRelay output typeRS485 interfaceModbus RTU/ASCIIAmbient temperatureDIN rail mountingWall mounting
    Learn More

  • MU110-24.8K Digital output module
    The digital output module MU110-24.8K has 8 digital outputs (NPN). The max. current load is 400 mA at 60 V DC. The outputs are galvanically isolated in groups of 4. The module requires 24 V DC power supply and supports Modbus RTU/ASCII communication via a serial RS485 interface. The enclosure provides IP20 rating and can be operated in the temperature range between -20 and +55 °C.
    8 digital outputsNPN output typeRS485 interfaceModbus RTU/ASCIIAmbient temperatureDIN rail mountingWall mounting
    Learn More

  • MU110-24.16R Digital output module
    The digital output module MU110-24.16R has 16 digital outputs (relay). The max. current load is 3 A at 250 V AC or 30 V DC. The outputs are galvanically isolated in groups of 4. The module requires 24 V DC power supply and supports Modbus RTU/ASCII communication via a serial RS485 interface. The enclosure provides IP20 rating and can be operated in the temperature range between -20 and +55 °C.
    16 digital outputsRelay output typeRS485 interfaceModbus RTU/ASCIIAmbient temperatureDIN rail mountingWall mounting
    Learn More

  • MU110-24.16K Digital output module
    The digital output module MU110-24.16K has 16 digital outputs (NPN). The max. current load is 400 mA at 60 V DC. The outputs are galvanically isolated in groups of 4. The module requires 24 V DC power supply and supports Modbus RTU/ASCII communication via a serial RS485 interface. The enclosure provides IP20 rating and can be operated in the temperature range between -20 and +55 °C.
    16 digital outputsNPN output typeRS485 interfaceModbus RTU/ASCIIAmbient temperatureDIN rail mountingWall mounting
    Learn More

  • MU110-24.6U analog output module
    The analog output module MU110-24.6U has 6 analog outputs (0-10 V). The available voltage value at the outputs is 12 ... 36 V DC. The module requires 24 V DC power supply and supports Modbus RTU/ASCII communication via a serial RS485 interface. The enclosure provides IP20 rating and can be operated in the temperature range between -20 and +55 °C.
    6 analog outputs0-10 V output signalRS485 interfaceModbus RTU/ASCIIAmbient temperatureDIN rail mountingWall mounting
    Learn More

Items 16 to 30 of 44 total

Page:
  1. 1
  2. 2
  3. 3