The MV210 DI series by akYtec stands out as a highly versatile and effective suite of digital input modules, optimized for a wide array of industrial automation scenarios. This series is distinguished by its utilization of the Modbus TCP protocol through Dual Port Ethernet interfaces, ensuring robust and reliable communication. Designed to cater to diverse operational needs, these modules are adept at handling various digital input types, enhancing system functionality and data acquisition efficiency.


15 digital inputs20 digital inputs32 digital inputsNPN input typePNP input typeEthernet interfacebypassModbus TCPUSB interfacebuilt-in real-time clockLoggingsoftware at no chargeAmbient temperatureDIN rail mountingWall mounting

* Required Fields

- +
Product Description
    Details

    The MV210 DI series by akYtec stands out as a highly versatile and effective suite of digital input modules, optimized for a wide array of industrial automation scenarios. This series is distinguished by its utilization of the Modbus TCP protocol through Dual Port Ethernet interfaces, ensuring robust and reliable communication. Designed to cater to diverse operational needs, these modules are adept at handling various digital input types, enhancing system functionality and data acquisition efficiency.

    Key Features of the MV210 Series:

    • Diverse Digital Input Capabilities: The MV210 series offers modules such as MV210-202, MV210-204, MV210-212, and MV210-214, each equipped with 20 to 32 digital inputs. These inputs are compatible with a range of signal types, including contact sensors, NPN/PNP transistors, and dry contacts, thereby offering extensive flexibility in sensor and device connectivity.
    • Advanced Communication Protocols: With dual Ethernet ports supporting Modbus TCP, these modules enable seamless integration and efficient data communication within automation systems. The inclusion of protocols like MQTT, SNMP, and SNTP further enhances their adaptability in modern industrial environments.
    • Environmental Resilience: Designed to operate reliably in temperatures ranging from -20 to +55 °C, the MV210 series ensures consistent performance even in demanding industrial conditions.
    • Ease of Configuration and Management: The series is accompanied by a user-friendly configurator, simplifying the setup process. Additionally, the capability for synchronous configuration updates aids in the efficient management of multiple modules, streamlining system maintenance and upgrades.

    Feature

    MV210-202

    MV210-204

    MV210-212

    MV210-214

    MV210-221

    Power Supply

    24 (10...48) V DC

    Power Consumption

    5 W

    9 W

    5 W

    Protection Against Reverse Polarity

    Yes

    Interface

    Dual Port Ethernet 10/100 Mbit

    Configuration Interface

    USB 2.0 (MicroUSB), Ethernet 10/100 Mbit

    Data Transfer Protocol

    Modbus TCP

    Protocol Version

    IPv4

    Digital Inputs Quantity

    20

    32

    15 (9 AC, 6 Dry Contact)

    Signal Type

    Contact sensor, NPN / PNP transistor

    Dry contact sensor, NPN transistor

    Contact sensor, NPN / PNP transistors

    Dry contact, NPN transistor

    AC voltage signal, Dry contact, NPN transistor

    Operation Modes

    Various

    Logical level detection, Pulse count

    Various

    Logical level detection, Pulse count

    Various

    Flash-memory (Log-file)

    Up to 100,000 cycles

    Real-time Clock Inaccuracy

    ±3 s/day at 25 °C, ±10 s/day at -40 °C and +55 °C

    Battery Type

    CR2032

    Lifetime of One Battery

    6 years

    Dimensions

    42×124×83 mm

    42×124×83 mm

    82×124×83 mm

    82×124×83 mm

    42×124×83 mm

    IP Code

    IP20

    Mean Time Between Failures

    60,000 h

    Average Service Lifetime

    10 years

    Weight

    0.4 kg

Additional Information
FAQ

    FAQ

    Are Mx210 modules compatible with third-party PLCs?
    MX210 modules are compatible with any third-party PLC device if it supports Modbus TCP, MQTT,SNMP or SNTP communication protocols.
    Rate the answer?
    What software is required to configure the module?
    Modules can be configured on a PC with a free software ToolPro from akYtec. Modules need to be connected to a PC with a micro USB or Ethernet cable. An external power supply unit is required in case an ethernet cable is used.
    Rate the answer?
    I have forgotten the module network settings. How can I find them?
    It is necessary to restore factory settings by pressing and holding the service button located under the front cover of the module for more than 12 seconds, all while the module is powered on. Now, the device will operate with default parameters.
    Rate the answer?
    Is there a feature for group configuration of multiple modules?
    Yes, MX210 extension modules have this ability.
    Rate the answer?
    Is there a possibility to disconnect the terminal block?
    Yes, terminal block for I/O connections is removable and enables quick and easy replacement of the device.
    Rate the answer?
    How many devices can the module connect to?
    Any MX210 extension module can simultaneously communicate with up to 4 TCP clients, which facilitates cabling and configuring of the control system.
    Rate the answer?
    How to perform connection with modules?
    Modules can be implemented into a star or chain/daisy-chain topology, the latter providing data transfer directly from port 1 to port 2 if the module fails due to device error or power loss, thanks to two bypass-capable Ethernet ports. The maximum length of communication lines is 100 m.
    Rate the answer?
    Are circuits galvanically isolated?
    Every device from Mx210 product line has galvanic isolation, which is performed differently for each model and in groups, such as power supply, inputs/outputs, interfaces and housing.
    Rate the answer?
    Can the integrated voltage source of a PR200-230.X.X be used for feeding an input module MV210?
    No, this voltage source cannot be used for feeding an MV210 module because it doesn’t provide enough current (max. 100 mA).
    Rate the answer?
    In which numeral system should the register address be written, decimal or hexadecimal?
    The register address has to be written in decimal.
    Rate the answer?
    How does the Modbus register work and why is it in hexadecimal (3x0000 to 3xFFFF)?
    Modbus registers are typically 16-bit values, used to store and exchange various types of data, such as sensor readings, control parameters, status information, etc. These registers are represented in a hexadecimal format and organized in a range from 0x0000 to 0xFFFF, which covers 65,536 possible values. The 16-bit format is common in industrial control systems because it provides a good balance between precision and data size. Hexadecimal representation of binary data is more compact, efficient and offers better readability for 16-bit values than binary or decimal, as each hexadecimal digit represents four binary bits. Hexadecimal values also align neatly with bytes. In a Modbus register, each byte is represented by two hexadecimal digits, making it easier to work with when dealing with byte-oriented communication protocols. Hexadecimal representation is consistent with the way data is displayed and configured in industrial control systems and related software. The "3x" in "3x0000 - 3xFFFF" refers to the Modbus function codes. In Modbus, function codes 3 and 4 are used for reading and writing registers. The "x" in "3x" signifies that these registers are in the "holding registers" category. Holding registers are used to store data that can be read and written by external devices.
    Rate the answer?
    What is the maximum permissible frequency that a digital input of the MV210 DIGITAL INPUT MODULE can handle in case of using this input to read an impulse signal?
    It depends on variant of device : MV210-202 (measuring frequency up to 100 kHz), MV210-204 (measuring frequency up to 400 Hz), MV210-212 (measuring frequency up to 100 kHz), MV210-214 (measuring frequency up to 400 Hz), MV210-221(measuring frequency up to 400Hz).
    Rate the answer?
    What are voltage/current thresholds of MV210 DI modules?
    For MV210-202/212 Digital inputs:
    Input current of logical 0 max. 1.2 mA
    Input current of logical 1 min. 5.5 mA
    Voltage range of logical 0 0.0…6.1 V
    Voltage range of logical 1 8.8…30.0 V
    Based on our experience, in case a digital input of MV210 does not register the applied voltage/current, it is possible that the values on the output of the power generator are not enough.