Welcome to akYtec!
 
Call us now: +49 (0) 511 / 16 59 672-0

PRM Extension module

SKU: PRM
PRM provides the quickest and the most convenient, as regards installation and configuration, digital or analog I/O extension for the PR200 Programmable Relay from akYtec. This module connects to the PR200 base unit directly over the internal bus, which ensures much faster and reliable communication as if it would be the case with RS485/Modbus. Moreover, the communication over the internal bus requires no additional I/O configuration as it is with Modbus registers.

8 digital or 4 analog inputs8 relay outputsGalvanic isolation between each group: Input, Output, Power Supply.Cost effectiveDIN rail mountingIP CodeAmbient temperature

* Required Fields

- +
Product Description
    Details

    The I/O Modules of the PRM series offer the easiest-to-implement solution to expand the number of inputs and outputs of the PR200 Programmable Relay from akYtec. Once a PRM module has been connected to a PR200, the PR200 treats the PRM's inputs and outputs as its own. Not only are no communication settings required as compared to establishing a similar communication using Fieldbus protocols but also the same high-speed performance as of the base unit (PR200) is kept.

    With one PRM unit, you can add 8 digital inputs and 8 relay outputs or 4 analog inputs and 2 analog outputs to your PR200. If you attach one more PRM, this number is doubled. The inputs and outputs are configurable, which means that you can set each of them for different signals and sensors choosing from 4-20 mA, 0-1V, various thermocouples and RTDs, switch contact, PNP, and many others.

    The PRM module is extremely quick and easy to install. It just has to be snapped onto a DIN rail and connected to the main device PR200 over an internal bus (a flexible bus cable is included in the scope of supply). The internal bus provides faster communication than a combination of RS485 and Modbus.

    As to supply voltage, the PRM extension module can be delivered in a version either for 24 VDC or for 230 VAC.

    Functions and features:
    • Possibility to expand PR200 with additional inputs and outputs without network protocols
    • Configurable inputs and outputs with various signals to choose from
    • Power supply independent from the main device
    • The same high-speed performance that of the main device
    • Safety output state
    • Easy connection, removal and replacement
    • Galvanic isolation between the power supply and I/O groups
    • Wide ambient temperature range

    Ordering information

    PRM - X - X
    Supply voltage
    230 (94...264) V AC 230
    24 (19...30) V DC 24
    I/O
    8 DI, 8 DO 1
    4 AI, 2 AO 3

    Variants

    PRM-230.1 extension module with 230 VAC supply voltage, 8 DI and 8 relay DO.
    PRM-24.1 extension module with 24 VDC supply voltage, 8 DI and 8 relay DO.
    PRM-230.3 extension module with 230 VAC supply voltage, 4 AI and 2 AO.
    PRM-24.3 extension module with 24 VDC supply voltage, 4 AI and 2 AO.
    PRM-230.1 PRM-230.3 PRM-24.1 PRM-24.3
    General
    Power supply 230 (90...264) V AC;
    50 (47...63) Hz
    24 (19...30) V DC
    Power consumption, max. 8 VA 4 W
    Mounting DIN rail (switchboard / distribution box)
    Ambient temperature -20...+55 °C
    IP code IP20
    Dimensions 80 x 108 x 58 mm
    Weight approx. 250 g
    Inputs
    Quantity 8 4 8 4
    Mode Digital Analog Digital Analog
    Type Switch contact RTD, TC, 0-4 kohm
    0(4)-20 mA, 0-1 V
    (the complete list)
    Switch contact
    PNP with open collector
    RTD, TC, 0-4 kohm
    0(4)-20 mA, 0-1 V
    (the complete list)
    Logical states 1 159...264 V AC (0.75...1.5 mA) - 15...30 V DC (5 mA) -
    0 0...40 V AC (0...0.5 mA) - -3...+5 V DC (0...1 mA) -
    Galvanic isolation in groups of 4 - in groups of 4 -
    ADC resolution - 16 bit - 16 bit
    Outputs
    Quantity 8 2 8 2
    Mode Digital Analog Digital Analog
    Type relay (NO) 4-20 mA, 0-10 V, 0-5 V, 0-20(24) mA relay (NO) 4-20 mA, 0-10 V, 0-5 V, 0-20(24) mA
    Galvanic isolation in groups of 2 in groups of 1 in groups of 2 in groups of 1
    Switching capacity AC 5 A, 250 V (resistive load) - 5 A, 250 V (resistive load) -
    DC 3 A, 30 V - 3 A, 30 V -
    Minimum load current 10 mA (at 5 V DC) - 10 mA (at 5 V DC) -
    DAC resolution - 12 bit - 12 bit
    Sensor Measuring range 
    Pt50, Pt100, Pt500, Pt1000 -200…+850°C
    Ni100, Ni500, Ni1000 -60…+180°C
    J -200…+1200°C
    N -200…+1300°C
    K -200…+1360°C
    S -50…+1750°C
    R -50…+1750°C
    B +200…+1800°C
    T -250…+400°C
    Standard signals
    0-1 V
    -50…+50 mV
    0-5 mA
    0-20 mA
    4-20 mA
    0…100%
    Resistive signals
    Resistance sensor 0-3950 ohm 0…100%
Additional Information

    programmable relay_extension module

    Programmable relay PR200 with two extension modules PRM-230.1 and PRM-24.1

FAQ

    FAQ

    How many PRM modules does the PR200 support?

    Maximum two modules can be connected in series to PR200.

    With these modules, you can extend the PR200 by up to 16 additional digital inputs and up to 16 digital outputs. Alternatively, if your system requires more I/O-points, you can use Modbus RTU/ASCII and connect up to 32 expansion modules over the RS485 interface. We recommend using our I/O-Modules of the Mx110 series for this purpose.

    Rate the answer?